CODE CLASSIFICATION Building Area - 41,275 sq. ft. (3836 sq. meters) Sprinklered 2 storeys Facing 1 street NBC 1995 F2 3,2,2,70 Max allowable area= 4,800 sq. meteres
|
TYPICAL EXTERIOR WALL 8" PRECAST WAFFLE PANELS R 20 IN WAFFLE 3 5/8" STEEL STUDS @ 16" O.C. R 12 INSULATION 6 MIL. CGSB POLY 1/2" DRYWALL |
TYPICAL INTERIOR DEMISING WALL 5/8" FIREGUARD 6' STEELS STUDS @ 16" o.c. R 20 INSULATION 6 MIL. CGSB POLY 5/8" FIREGUARD 1 HR. F.R. ULC W 409 |
TYPICAL FRONT WALL DRYVIT SYSTEM 1/2" DRYWALL 20 GA. STEEL STUDS @ 16" O.C. R 20 INSULATION 6 MIL. CGSB POLY 1/2" DRYWALL |
||
LOAD BEARING STEEL STUDS WALL 3 5/8" 16 GA. STEEL STUDS 5/8" FIREGUARD E.S. R 12 INSULATION 1 ROW BRIDING CHANNEL G.A. FILE NO. WP1206 DESIGN U425 |
TYPICAL WAREHOUSE OFFICE 5/8" FIREGUARD 6 MIL. CGSB POLY 3 5/8" STEEL STUDS R 12 INSULATION 5/8" FIREGUARD 1 HR. F.R. - ULC W415 |
TYPICAL STAIRSHAFT 5/8" FIREGUARD 6 MIL. CGSB POLY 3 5/8" STEEL STUDS R 12 INSULATION 5/8" FIREGUARD 1 H.R. F.R. - ULC W415 |
||
TYPICAL INTERIOR OFFICE WALL 1/2" DRYWALL 3 5/8" STEEL STUDS @ 16" O.C. R 8 INSULATION 1/2" DRYWALL |
12' X 14' STEEL INSULATED O.H. DOOR R16 THERMACORE or EQUAL 2 - 8" X 18" THERMOSEALED WINDOW HI-LIFT 3/4 h.p. OPERATION 3" CONT. HD. HARDWARE WEATHER STRIPPING ALL AROUND PNEUMATIC REVERSING |
8' X 10' STEEL INSULATED O.H. DOOR R16 THERMACORE or EQUAL 1 - 8" X 18" THERMOSEALED WINDOW HI-LIFT MANUAL OPERATION 3" CONT. HD. HARDWARE WEATHER STRIPPING ALL AROUND TOE PLATE FOR CLOSING |
To print this page, please click on the printer to open a separate, resizable window which is printer-friendly. |